Specifications
Apollo SL50 / SL60 Installation Manual
29
SECTION 3 - SPECIFICATIONS
This section includes detailed electrical, physical, environmental, and performance
specifications for the Apollo SL50 and SL60.
ELECTRICAL
Input voltage............................................. 10VDC to 40VDC, reverse polarity protected
Input current (GPS navigation input) ....... 325mA typical, 500mA max at 13.75VDC
170mA typical, 350mA max at 27.5VDC
Input current (comm input) ...................... 270mA typical, 2A max at 13.75VDC, receive
130mA typical, 900mA max at 27.5VDC, receive
2.1A typical, 3.2A max at 13.75VDC, transmit
1.0A typical, 1.4A max at 27.5VDC, transmit
Note: receive max at full receive audio, transmit
max at 90% modulation at 1000Hz
Input power (GPS navigation input)......... 4.7 watts typical
Input power (comm input)........................ 3.7 watts typical, receive
28 watts typical, transmit
Internal fuses ............................................ Nav input: 3 amp fast blow, surface mount on board
Comm input : 7 amp fast blow, soldered in board
Memory backup........................................ Internal lithium battery with a service life of
approximately 4 to 6 years. See Appendix B for
battery replacement instructions.
Note: The SL50/60 will provide a message on the display when the lithium battery is
running low and needs replacement.
PHYSICAL
Height ....................................................... 1.30 inches (3.30 cm)
Width........................................................ 6.25 inches (15.88 cm)
Depth ........................................................ 11.452 inches (29.09 cm) behind panel, including
mounting frame and connectors
Weight (with mounting frame)................. SL50: 2.3 lb. (1.04 kg)
SL60: 2.8 lb. (1.27 kg)
ENVIRONMENTAL
The Apollo SL50 and SL60 units are designed and tested to meet appropriate categories of
RTCA/DO-160C or DO-160D. The Environmental Qualification Form is included in
Appendix C.
Operating temperature.............................. -20°C to +55°C